Whether health monitoring is on. Health monitoring is Synapticon's name for reporting the iC-MU's
NON_CTR error, the period counter consistency error, in the error bit.
CFGEW (register 0x0C) bit 6 enables NON_CTR in the error bit when 0 and disables it when 1. Motion Master
writes 0x6C by default, which disables it, and 0x2C when a full calibration is asked to activate health
monitoring. The two differ in bit 6 only.
Whether health monitoring is on. Health monitoring is Synapticon's name for reporting the iC-MU's
NON_CTRerror, the period counter consistency error, in the error bit.CFGEW(register 0x0C) bit 6 enablesNON_CTRin the error bit when 0 and disables it when 1. Motion Master writes 0x6C by default, which disables it, and 0x2C when a full calibration is asked to activate health monitoring. The two differ in bit 6 only.